Company Products
Indoor Outdoor IP Waterproof Museum
Solutions
Museums and showcasesJewellery and watch storesOffices and schoolsGardens and outdoor
Tools
Track configurator Display case calculator
Articles
SKILL, the case that measures light
Quote List (0) Private Area Contacts
IT EN FR DE
Private Area Quote List 0
EN

We use anonymous technical and analytical cookies. Info

Garden lighting

Lighting a park or a private garden without wasting light towards the sky, without glare and without disturbing wildlife: the figures, the rules and the usual mistakes.

Lighting a garden is the opposite of lighting an office. In an office you start from a level to be reached; in a garden you start from darkness, which is the normal condition of the place, and you add only the light needed to walk, to recognise a face and to see what is worth seeing. At night the eye is dark adapted: a few lux are enough to make a surface look bright.

The design therefore balances three constraints pulling in different directions: how much light is really needed, how much is wasted towards the sky — the reason projects get rejected by local authorities — and how much disturbance is caused to what lives in the garden, night insects and animals included.

1. How many lux: far fewer than expected

The reference for public outdoor areas is EN 12464-2; for roads and driveways EN 13201 applies. Private gardens have no binding level, but sensible values are these.

AreaAverage illuminanceNote
Private footpath5 – 10 luxuniformity matters more than peak value
Steps, level changes, ramps20 luxgrazing light, never into the eyes
Seating area, outdoor table20 – 50 luxseveral soft points beat one strong one
Driveway entrance, gate10 – 20 luxat road level
Facade or boundary wall2 – 5 cd/m²expressed as luminance, not lux
Tree canopy15 – 30 luxon the foliage, from below or above

Peak value matters less than the ratio between areas. A path at 40 lux next to a dark lawn reads worse than one at 8 lux in a uniformly dim garden, because the eye adapts to the brightest point and everything else disappears. Practical rule: keep the ratio between adjacent areas below 1 to 5.

2. Light pollution: the constraint that rejects projects

In Italy there is no national law: the matter is ruled by regional laws, nearly all derived from Lombardy law 17/2000. The recurring requirement is sharp and easy to check:

luminous flux emitted above the horizontal plane = 0 %
(ULOR = 0, in the installed position)

Two phrases deserve attention. Above the horizontal plane: what counts is not the luminaire but the way it is mounted — a compliant luminaire tilted by 20° is no longer compliant. In the installed position: verification happens on site, not in the catalogue.

The technical standard defining quantities and methods is UNI 10819. Beyond ULOR, most regions also require night switch off or dimming, forbid beams aimed at the sky except for monuments, set minimum efficiency for road installations and forbid lighting areas outside the property boundary.

NON COMPLIANT sky floodlight tilted upwards flux to the sky: 33 % COMPLIANT sky narrow optic into the canopy flux to the sky: 0 % horizontal plane
Same floodlight, two tilts: on the left a third of the flux ends above the horizon (non compliant), on the right the beam stays inside the canopy.
In practice. A ground floodlight aimed upwards is by far the biggest problem: all the flux missing the canopy goes to the sky. Compliance comes from narrow optics aimed into the foliage, glare shields and a curfew — or by lighting the tree from above, from a pole or a branch, which is the most elegant solution and carries no regulatory limit.

3. Glare: you should see what is lit, not the lamp

4. Light and nature: why colour matters

Artificial light at night is now recognised as an environmental pressure, and the measured effects depend mostly on the blue content of the spectrum, below 500 nm: night insects are attracted, bats lose flight corridors, migrating birds are disoriented by vertical beams, and trees near luminaires shift their phenology. Hence the colour temperature choice is technical, not aesthetic: 3000 K maximum, 2700 K where green must stay alive, 2200 K amber in natural areas or near watercourses.

Greens and browns are saturated colours: a LED with Ra ≥ 90 and decent R9 renders foliage as seen by day, while a cheap LED turns it grey-blue.

5. Designing in layers, not in luminaires

SAFETY paths, steps, entrances 5 - 20 lux · always on ORIENTATION bollards, wall recessed, low walls low grazing light SCENE trees, sculptures, water narrow beam · off after hours LIVING table, outdoor kitchen, relax 20 - 50 lux · warm and dimmable
The four layers: they switch on at different times and only the first stays on all night.

6. Durability: what actually kills outdoor installations

Outdoor systems die of water and corrosion, not of light: IP65 on walls and poles, IP67 in the ground, IP68 underwater; IK08 where a mower passes; marine grade anodised aluminium or AISI 316 near the sea; buried grade cable with resin joints or inspection pits; drainage under every ground recessed unit; drivers kept out of the soil. On voltage, 24 V SELV simplifies trenching and is almost mandatory near pools, but beyond 20-25 m of cable the voltage drop becomes visible.

7. What to write in a specification

8. Frequently asked questions

How many lux does a garden need?

Far fewer than people assume, because at night the eye is dark adapted. A private footpath is safe with 5-10 average lux, a step or a level change with 20 lux, a seating area or outdoor table with 20-50 lux, a driveway entrance with 10-20 lux. Above those values you do not see better: you see worse, because unlit areas turn black and the eye can no longer adapt.

What does Italian law say about light pollution?

There is no national law: the matter is ruled by regional laws, nearly all modelled on Lombardy law 17/2000. The common requirement is zero luminous flux emitted above the horizontal plane in the installed position, that is ULOR equal to zero per cent, with few exemptions for monuments. Many regions also impose switch off or dimming at night and forbid beams aimed at the sky. The technical reference standard is UNI 10819.

Is a floodlight aimed at a tree compliant?

It depends on shielding and on where the light that misses the canopy ends up. A ground floodlight firing upwards emits flux above the horizon and in many regions is allowed only for monumental heritage, with power and curfew limits. In practice compliance comes from narrow optics aimed into the canopy, glare shields and a switch off time: the foliage intercepts the light and what passes beyond must be negligible.

Which colour temperature for a garden?

Low. Wildlife guidance and recent regulations ask for 3000 K maximum, dropping to 2200 K amber in natural areas or near watercourses. The reason is blue content: the component below 500 nm attracts night insects, disorients bats and alters plant rhythms. At 2200 K lawn green looks dull, so 2700 K is often the compromise in ornamental gardens.

Which ingress protection is needed outdoors?

IP65 for wall or pole luminaires, IP67 for ground recessed units exposed to standing water, IP68 for underwater installation in pools and ponds. Mechanical strength matters too, IK08 or better where a mower passes, and so does corrosion: near the sea use marine grade anodised aluminium or AISI 316 stainless steel, since AISI 304 stains within a few seasons.

230 V or 24 V in the garden?

Extra low voltage 24 V simplifies trenching and maintenance, allows work on the system without electrical risk and is almost mandatory near pools. The limit is voltage drop: beyond 20-25 m of cable with ordinary cross sections the light visibly falls off, so either several drivers are distributed or the system moves to 230 V with class I or II luminaires.

9. From design to installation

Three choices decide the result: fewer lux than instinct suggests, because at night contrast matters more than level; no flux above the horizon, which is both the legal constraint and the measure of how much light is being thrown away; warm spectrum with high rendering, which protects wildlife and shows green as it should be. Poles, recessed units and floodlights come afterwards, and that is the easy part.

Sources. Illuminance values from EN 12464-2, UNI 11248 and EN 13201; upward flux requirements from Italian regional light pollution laws and UNI 10819; wildlife and colour temperature guidance from published recommendations for the protection of nocturnal ecosystems. The applicable regional law and municipal regulation always prevail.
See the outdoor luminaires